| The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions. |
| thanks to its comprehensive assortment of options and accessories. | | | | | |
| | | | | | | |
| BENEFITS | | | | | | |
| Safe – cell cultures receive maximum protection against contamination | | | | | |
| Reliable – constant well-being conditions for the cells | | | | | | |
| Smart – simple routine cleaning and convenient operation | | | | | | |
| Economical – efficient operation without consumables | | | | | | |
| | | | | | | |
| FEATURES | | | | | | |
| Optimized double-pan humidification system with condensation protection | | | | | |
| Tried-and-tested anti-contamination concept with 18°C hot air sterilization | | | | | |
| Hot-air sterilizable CO₂ sensor with single-beam infrared technology | | | | | |
| Seamless inner chamber made of stainless steel with flanges as shelf support system | | | | | |
| Fanless interior with Venturi CO₂ gas mixing nozzle | | | | | | |
| Intuitive touchscreen controller | | | | | | |
| Internal data recording, can be read out in open format via USB interface | | | | | |
| Fault diagnosis system with visual and acoustic alarm | | | | | | |
| Interfaces: Ethernet, USB, zero-voltage alarm contact | | | | | | |
| Fail-safe CO₂ system for protecting the pH of cell cultures | | | | | | |
| | | | | | | |
| OPTIONAL EQUIPMENT | | | | | | |
| Stacking adapter | | | | | | |
| CO₂ gas tank changer | | | | | | |
| CO₂ - shaker | | | | | | |
| Copper interior fittings | | | | | | |
| Services | | | | | | |
| BINDER INDIVIDUAL | | | | | | |
| | | | | | | |
| TECHNICAL DATA | | | | | | |
| Description | CB 56 | CB 170 | CB 260 | | | |
| Measures | | | |
| Interior volume [L] | 53 | 170 | 267 | | | |
| Net weight of the unit (empty) [kg] | 53 | 98 | 125 | | | |
| Permitted load [kg] | 30 | 30 | 40 | | | |
| Load per rack [kg] | 10 | 10 | 10 | | | |
| Wall clearance back [mm] | 100 | 100 | 100 | | | |
| Wall clearance sidewise [mm] | 50 | 50 | 50 | | | |
| Internal Dimensions | | | |
| Width [mm] | 400 | 560 | 620 | | | |
| Height [mm] | 400 | 600 | 750 | | | |
| Depth [mm] | 330 | 505 | 575 | | | |
| Housing dimensions not incl. fittings and connections | | | |
| Width [mm] | 528 | 680 | 740 | | | |
| Height [mm] | 674 | 870 | 1020 | | | |
| Depth [mm] | 545 | 715 | 785 | | | |
| Performance Data Temperature | | | |
| Temperature range +4-6 °C above ambient temperature to [°C] | 60 | 60 | | | | |
| Temperature range +5-6 °C above ambient temperature to [°C] | | | 60 | | | |
| Temperature variation at 37°C [± K] | 0.3 | 0.3 | 0.4 | | | |
| Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 | 0.1 | | | |
| Recovery time after 30 seconds door open at 37 °C [min] | 5 | 6 | 6 | | | |
| Performance Data Climate | | | |
| Humidity range [% RH] | 90…95 | 90…95 | 90…95 | | | |
| CO₂-Data | | | |
| CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | | | |
| CO₂ measurement | IR | IR | IR | | | |
| Electrical data | | | |
| Nominal power (version 120 V) [kW] | 0.8 | 1.4 | 1.5 | | | |
| Nominal power (version 230 V) [kW] | 0.8 | 1.4 | 1.5 | | | |
| Fixtures | | | |
| Number of shelves (std./max.) | 2/3 | (3/6) | 3/8 | | | |
| | | | | | | |
| | | | | | | |